MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40001-024-02080-3

Медицинская библиотека · European journal of medical research · 2024

Dosimetric comparison of multiple SBRT delivery platforms for pancreatic cancer.

Song Yongchun, Chen Xiuli, Yu Xuyao, Dong Yang, Tian Jia, Wang Xin, Wang Yuwen, Jiang Bo

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Stereotactic body radiation therapy (SBRT) has been widely used for pancreatic cancer. However, there is still a lack of studies comparing the latest SBRT techniques in terms of clinical efficacy and safety.

OBJECTIVES

This study aims to evaluate three latest SBRT delivery platforms: CyberKnife (CK), Tomography Radixact (TOMO), and Halcyon volume rotation intensity modulation therapy (VMAT) for the treatment of pancreatic cancer.

METHODS

Sixteen patients with pancreatic cancer treated with CK were retrospectively analyzed. SBRT plans were designed using Precision and Eclipse software. CK plans were optimized in two forms: fixed collimator (CK-Fixed) and multi-leaf grating collimator (CK-MLC). TOMO plans were designed with 2.5 cm Fixed Jaw, pitch 0.123-0.43 and 4.0 modulation factors in precision system. In Eclipse 15.6 system, photon optimizer (OP) algorithm was used to design the coplanar two-arc Halcyon VMAT. The median radiation dose was 40 Gy (35-45 Gy) in 5 fractions. The effectiveness of clinical treatment was evaluated by comparing the homogeneity index (HI), conformity index (CI), coverage of the planning target volume (PTV) and dose distribution parameters of organs at risk (OAR).

RESULTS

All plans met the limits of clinical target dose and OAR. CK-MLC plans had the lowest maximum dose of 2 cm normal tissue from PTV margin (D2cm), indicating a low risk of peripheral radiation damage. Additionally, the CK-MLC plans had the lowest dose parameters and provided the best protection for the kidney, spinal cord, small intestine, and duodenum, with a paired t-test p < 0.05, indicating a statistical difference.

CONCLUSION

High conformity and adjustability of CK-MLC allowed for precise complex target localization and conformal dose distribution, benefiting tumor treatment while maximally reducing damage to OAR. This study provides valuable dosimetric evidence for SBRT technique selection for pancreatic cancer.

Для цитирования: Song Yongchun, Chen Xiuli, Yu Xuyao, Dong Yang, Tian Jia, Wang Xin, Wang Yuwen, Jiang Bo. Dosimetric comparison of multiple SBRT delivery platforms for pancreatic cancer.. European journal of medical research. 2024. DOI: 10.1186/s40001-024-02080-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.