MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00381-008-0682-9

Медицинская библиотека · Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2008

Intraoperative infrared brain surface blood flow monitoring during superficial temporal artery-middle cerebral artery anastomosis in patients with childhood moyamoya disease.

Nakagawa Atsuhiro, Fujimura Miki, Arafune Tatsuhiko, Sakuma Ichiro, Tominaga Teiji

Клинический случайСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To monitor patency of the bypass and to accomplish comprehensive visualized evaluation of brain surface hemodynamics in childhood moyamoya patients, we performed intraoperative monitoring using novel infrared imaging system.

MATERIALS AND

METHODS

Intraoperative monitoring of brain surface blood flow by IRIS V infrared imaging system has been conducted during superficial temporal artery-middle cerebral artery anastomosis on seven sides of five pediatric patients with moyamoya disease (man/woman = 2:3, 7-8 years old). The range of recipient artery was 0.7-0.8 mm (average 0.75 mm). Magnetic resonance imaging and magnetic resonance angiography were performed routinely before and after surgery.

CONCLUSIONS

In all cases, patency of bypass, as well as detailed local hemodynamics and changes of brain surface temperature distribution could be evaluated. Intraoperative infrared system will be a feasible monitoring not only for noninvasive intraoperative evaluation of bypass patency but also for local hemodynamics even in patients with childhood moyamoya disease.

Для цитирования: Nakagawa Atsuhiro, Fujimura Miki, Arafune Tatsuhiko, Sakuma Ichiro, Tominaga Teiji. Intraoperative infrared brain surface blood flow monitoring during superficial temporal artery-middle cerebral artery anastomosis in patients with childhood moyamoya disease.. Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery. 2008. DOI: 10.1007/s00381-008-0682-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.