MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/ch-242305

Медицинская библиотека · Clinical hemorheology and microcirculation · 2024

Clinical applications of superb microvascular imaging and virtual touch imaging quantification in pediatric mesenteric lymphadenitis diagnosis: A promising pathway to enhanced precision.

Zhu Yi-Cheng, Zhou Li, Zu Dao-Ming, Deng Shu-Hao, Zhang Yuan, Shan Jun, Shi Xiu-Rong, Jiang Quan

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Mesenteric lymphadenitis (ML) demonstrates a distinctive inclination for the pediatric and adolescent demographic and the diagnosis of ML in young children poses a substantial challenge.

OBJECTIVE

This prospective study aimed to assess the diagnostic efficacy of Superb Microvascular Imaging (SMI) and Virtual Touch Tissue Imaging quantification (VTIQ) in distinguishing pediatric mesenteric lymphadentitis.

METHODS

We examined 82 mesentric lymph node (MLN) in pediatric patients with mesenteric lymphadentitis and 50 MLN in a healthy group. SMI was utilized to evaluate vascularity within the MLN, while MLN stiffness, quantified as shear wave velocity (SWV) in meters per second (m/s), was assessed using VTIQ. We compared the diagnostic performance of greyscale Ultrasound, US combined with SMI, US combined with VTIQ, and US combined with both SMI and VTIQ.

RESULTS

SMI revealed a significant distinction between mesenteric lymphadentitis and normal MLN (p < 0.001). MLN affected by mesenteric lymphadentis exhibited increased vascularity (marked vascularity: 13/82, 15.85%) compared to normal MLN (marked vascularity: 1/50, 2.00%). Statistically significant differences were observed in SWV values beween mesenteric lymphadentitis and normal MLN (all p-values <0.001). The mean and minimum SWV values for MLN with mesenteric lymphadentitis were 1.66±0.77 m/s and 1.51±0.53 m/s, respectively. Control group SWV values were approximately three times higher than those in the mesenteric lymphadenitis group. The highest area under the curve values were achieved with the combination of all three modalities (0.837, 95% confidence interval: 0.763- 0.896), followed by US + VTIQ (0.795, 0.716- 0.860), US + SMI (0.753, 0.670- 0.824) and US alone (0.642, 0.554- 0.724).

CONCLUSION

SMI and VTIQ offer a promising noninvasive adjunct to grayscale ultrasound for identifying mesenteric lymphadentitis in pediatric patients.

Для цитирования: Zhu Yi-Cheng, Zhou Li, Zu Dao-Ming, Deng Shu-Hao, Zhang Yuan, Shan Jun, Shi Xiu-Rong, Jiang Quan. Clinical applications of superb microvascular imaging and virtual touch imaging quantification in pediatric mesenteric lymphadenitis diagnosis: A promising pathway to enhanced precision.. Clinical hemorheology and microcirculation. 2024. DOI: 10.3233/ch-242305.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.