Incidence of cardiac arrhythmias with therapeutic versus diagnostic ultrasound and intravenous microbubbles.

Chapman Scott, Windle John, Xie Feng, McGrain Anna, Porter Thomas R

СтатьяПоддержка NIH: внешняя программаПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

The purpose of this study was to determine the type of arrhythmias induced with therapeutic versus diagnostic transthoracic low-frequency ultrasound (TLFUS) transducers in the presence of intravenous microbubbles.

METHODS

Intravenous perfluorocarbon-exposed sonicated dextrose albumin (PESDA) microbubbles were infused or given as a bolus injection while TLFUS was applied in the standard parasternal and apical views with either a 1-MHz therapeutic ultrasound transducer or high-mechanical-index diagnostic ultrasound (1.7 MHz).

RESULTS

Significantly more ectopy was produced by the therapeutic transducer, especially at higher-intensity settings in the continuous wave mode after bolus injections of PESDA (P < .001 compared with lower intensities and lower continuous infusion rates). Six patients (15%) had either clinical supraventricular tachycardia or nonsustained ventricular tachycardia after intravenous PESDA with therapeutic TLFUS. In comparison, diagnostic high-mechanical-index ultrasound produced only isolated ventricular ectopy and no sustained ventricular arrhythmias.

CONCLUSIONS

Intravenously injected microbubbles and low-frequency therapeutic transducers operating at longer duty cycles and wide beam widths have the capability of eliciting clinically important arrhythmias in patients at high risk for such events.

Для цитирования: Chapman Scott, Windle John, Xie Feng, McGrain Anna, Porter Thomas R. Incidence of cardiac arrhythmias with therapeutic versus diagnostic ultrasound and intravenous microbubbles.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2005. DOI: 10.7863/jum.2005.24.8.1099.