MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/s0022215115001814

Медицинская библиотека · The Journal of laryngology and otology · 2015

Pulse oximetry in paediatric obstructive sleep apnoea: is it used appropriately?

Kanona H, Sharma S, Chaidas K, Kotecha B

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study assessed the use of pulse oximetry testing in children with suspected obstructive sleep apnoea in a hospital setting.

METHODS

A retrospective review of patients who underwent pulse oximetry testing between April 2013 and October 2013 was performed. Primary outcome measures included positive pulse oximetry results, defined as a McGill oximetry score of 2-4.

RESULTS

Thirty-seven test results were usable for analysis: from 21 pre- and 16 post-operative tests. Only four patients had positive test results. There was a significant difference between pre- and post-operative quality of life outcome scores in the surgical group (p < 0.0001).

CONCLUSION

Pre-operative pulse oximetry should be used as a guide to help triage patients who require specialist paediatric services, such as a paediatric intensive care unit. The use of pulse oximetry, particularly in the post-operative setting, is unlikely to change patient management and can incur unnecessary financial costs to UK National Health Service Hospital Trusts.

Для цитирования: Kanona H, Sharma S, Chaidas K, Kotecha B. Pulse oximetry in paediatric obstructive sleep apnoea: is it used appropriately?. The Journal of laryngology and otology. 2015. DOI: 10.1017/s0022215115001814.