Медицинская библиотека · Dermatitis : contact, atopic, occupational, drug · 2012

Sensitization prevalence for benzalkonium chloride and benzethonium chloride.

Dao Harry, Fricker Chris, Nedorost Susan T

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Benzalkonium chloride (BAK) and benzethonium chloride (BEC) are well-characterized skin irritants and rare sensitizers, but optimal testing for allergic contact dermatitis (ACD) is not established.

OBJECTIVE

Sensitization prevalence was sought, and several patch testing concentrations and vehicles were compared.

METHODS

One hundred forty-two patients tested to the standard screening series for evaluation of dermatitis consented to additional tests including BAK 0.15% aqueous (aq), BAK 0.15% petrolatum (pet), BEC 0.15% aq, and BEC 0.5% aq. Follow-up to assess clinical relevancy included early and late patch test reads, 1-month clinical follow-up, and long-term phone calls. Patients were categorized as definite, possible, or unlikely to have ACD to BAK and/or BEC.

RESULTS

Atopy was not associated with patch test reactions (P = 0.154). Seventy-five percent (6/8) of the patients with possible ACD to BAK had coreactions with BEC. Testing to both BAK 0.15% pet and 0.15% aq would have identified 91% of those with possible ACD to BAK, twice as many than if only BAK 0.1% aq from the standard series was used.

CONCLUSION

Sensitization to BAK and BEC, although rare, does occur. Weak and morphologically irritant reactions at day 7 reading can be relevant. We recommend testing to BAK 0.15% aq and 0.15% pet to increase sensitivity and having patients undergo long-term follow-up.

Для цитирования: Dao Harry, Fricker Chris, Nedorost Susan T. Sensitization prevalence for benzalkonium chloride and benzethonium chloride.. Dermatitis : contact, atopic, occupational, drug. 2012. DOI: 10.1097/der.0b013e318260d78d.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.