MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1373/clinchem.2015.252494

Медицинская библиотека · Clinical chemistry · 2016

Diagnosis and Monitoring of Cystinosis Using Immunomagnetically Purified Granulocytes.

Gertsman Ilya, Johnson Wynonna S, Nishikawa Connor, Gangoiti Jon A, Holmes Bonnie, Barshop Bruce A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Cystine determination is a critical biochemical test for the diagnosis and therapeutic monitoring of the lysosomal storage disease cystinosis. The classical mixed-leukocyte cystine assay requires prompt specialized recovery/isolation following blood drawing, providing cystine concentrations normalized to total protein from assorted types of white blood cells, each with varying cystine content.

METHODS

We present a new workflow for cystine determination using immunomagnetic granulocyte purification, and new reference ranges established from 47 patient and 27 obligate heterozygote samples assayed. Samples were collected in acid-citrate dextrose tubes and their stability was proven to allow for overnight shipping before analysis. Cystine was quantified by LC-MS/MS.

RESULTS

The new method was reproducible (<15% root mean square error) and specific, assaying purified granulocytes from blood samples that no longer required immediate preparation and therefore allowing for up to 30 h before processing. There was a nearly a 2-fold increase in the therapeutic target (1.9 nmol half-cystine/mg protein) range, established using distributions of patient, obligate heterozygote, and control samples. The 2.5-97.5 percentile ranges (-2 SD to +2 SD around mean) for these cohorts were 0.67-6.05 nmol/mg protein for patients, 0.33-1.35 nmol/mg protein for obligate heterozygotes, and 0.09-0.35 nmol/mg protein for controls.

CONCLUSIONS

The intracellular cystine determination method using immunopurified granulocytes followed by LC-MS/MS analysis improves the inherent variability of mixed leukocyte analysis and eliminates the need for immediate sample preparation following blood draw.

Для цитирования: Gertsman Ilya, Johnson Wynonna S, Nishikawa Connor, Gangoiti Jon A, Holmes Bonnie, Barshop Bruce A. Diagnosis and Monitoring of Cystinosis Using Immunomagnetically Purified Granulocytes.. Clinical chemistry. 2016. DOI: 10.1373/clinchem.2015.252494.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.