m+Medelevator.RU
← Поиск публикаций
Interactive cardiovascular and thoracic surgery · 2019

Mechanical versus biological valve prosthesis for surgical aortic valve replacement in patients with infective endocarditis.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kytö Ville, Ahtela Elina, Sipilä Jussi, Rautava Päivi, Gunn Jarmo

Аннотация

OBJECTIVES: The optimal choice of valve prosthesis in surgical aortic valve replacement for infective endocarditis (IE) is controversial. We studied outcomes after mechanical versus biological prosthetic valve surgical aortic valve replacement in IE patients.

METHODS: All patients with native-valve IE aged 16-70 years undergoing mechanical or biological surgical aortic valve replacement in Finland, between 2004 and 2014, were retrospectively studied (n = 213). Outcomes were all-cause mortality, ischaemic stroke, major bleeding and aortic valve reoperation at 1 year and 5 years. Results were adjusted for baseline features (age, sex, comorbidity burden, atrial fibrillation, valvular stenosis, concomitant coronary artery bypass grafting, extension, urgency, year and centre of operation). Median follow-up was 5 years.

RESULTS: The 5-year mortality rate was 19.0% with mechanical prostheses and 34.8% with biological prostheses [hazard ratio (HR) 0.47, 95% confidence interval (CI) 0.23-0.92; P = 0.03]. Ischaemic stroke rates were 8.3% with mechanical prostheses and 16.8% with biological prostheses at 5 years (HR 0.21, CI 0.06-0.79; P = 0.01). Results were comparable in patients aged 16-59 and 60-70 years (interaction P = 0.84). Major bleeding within 5 years was similar between mechanical (11.3%) and biological valve (13.4%) groups (P = 0.95) with comparable rates of both gastrointestinal and intracranial bleeds. Reoperation rates at 5 years were 5.0% for mechanical prostheses and 9.2% for biological prostheses (P = 0.14). The 1-year ischaemic stroke rate was lower with mechanical prostheses (3.6% vs 11.6%, P =0.03), whereas mortality, major bleeding and reoperation rates were similar between groups.

CONCLUSIONS: The use of mechanical aortic valve is associated with lower mid-term mortality compared to biological prosthesis in patients with native-valve IE aged ≤70 years. Our results do not support the routine choice of a biological aortic valve prosthesis in this patient group.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты