MedElevator Войти в исследования
← Поиск публикаций

DOI 10.23736/s0021-9509.19.10783-5

Медицинская библиотека · The Journal of cardiovascular surgery · 2019

Preclinical and clinical evaluation of a novel synthetic bioresorbable, on-demand, light-activated sealant in vascular reconstruction.

Pellenc Quentin, Touma Joseph, Coscas Raphael, Edorh Grégoire, Pereira Maria, Karp Jeffrey, Castier Yves, Desgranges Pascal, Alsac Jean Marc

Клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Synthetic vascular material use, particularly polytetrafluoroethylene- (PTFE) -based, can be associated with bleeding, which may increase operative time and blood loss. None of the commercially available sealants designed to ensure hemostasis combine bioresorption, high viscosity, hydrophobicity, and compliance with the underlying tissue and on-demand activation.

METHODS

A study was designed to assess the biocompatibility and in-vivo performance and bioresorption of a new synthetic on-demand light-activated poly(glycerol-sebacate) acrylate- (PGSA) -based SETALIUM™ Vascular Sealant (TISSIUM, Paris, France) in three large animal studies of open vascular carotid and aortic surgery. The pre-clinical results were then translated into a clinical setting in a prospective, single-arm multicenter study in patients requiring carotid endarterectomy using an ePTFE patch.

RESULTS

The biocompatibility testing showed that the PGSA-based SETALIUM™ Vascular Sealant did not induce any significant toxic reaction at a standard clinical dose nor at doses up to 40 times the equivalent intended clinical dose. The PGSA-based sealant was shown to be non-pyrogenic, non-sensitizing, non-irritant, non-clastogenic, and non-mutagenic. The animal studies showed excellent performance and safety results, with clinically significant hemostasis achieved in 100% of the animals in both carotid and aorta studies and excellent local tolerance. Histopathology and morphometric analyses showed surface-based gradual and sustained bioresorption of the PGSA-based sealant up to 86% at 12 months. In the clinical study, the application of the PGSA-based sealant resulted in good performance and safety, with immediate hemostasis achieved in 84% of the cases and no adverse event related to the sealant reported through the one-year follow-up.

CONCLUSIONS

The new synthetic on-demand light activated PGSA-based SETALIUM™ Vascular Sealant investigated in our studies demonstrated good biocompatibility, sustained and gradual surface based bioresorption, and acceptable safety profile in animal studies. In addition, the first in-human use showed that the sealant is a safe and effective alternative to achieve fast and controlled hemostasis in vascular carotid reconstructions. A larger randomized controlled study will allow further validation of these encouraging preliminary results.

Для цитирования: Pellenc Quentin, Touma Joseph, Coscas Raphael, Edorh Grégoire, Pereira Maria, Karp Jeffrey, Castier Yves, Desgranges Pascal, Alsac Jean Marc. Preclinical and clinical evaluation of a novel synthetic bioresorbable, on-demand, light-activated sealant in vascular reconstruction.. The Journal of cardiovascular surgery. 2019. DOI: 10.23736/s0021-9509.19.10783-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.