Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2014

Enzymatic diagnosis of homocystinuria by determination of cystathionine-ß-synthase activity in plasma using LC-MS/MS.

Alcaide P, Krijt J, Ruiz-Sala P, Ješina P, Ugarte M, Kožich V, Merinero B

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Cystathionine β-synthase (CBS) is released into plasma from organs expressing this enzyme. Decreased plasma CBS activity has been demonstrated in CBS-deficient patients with 16 different genotypes. The aim of this study was to determine plasma CBS activity in patients carrying 11 additional genotypes using two LC-MS/MS methods. Patients and methods CBS activity was measured in EDTA or heparin plasma using either a previously described or a newly developed LC-MS/MS method optimized for analysis of the reaction product, 3,3-(2)H2-cystathionine, as its butyl ester derivative. We analyzed plasma samples from 26 CBS-deficient patients with known genotypes and 57 controls.

RESULTS

We developed a new LC-MS/MS method for simple and sensitive determination of CBS activity. Plasma CBS activity was low (i.e., 0.001-0.036 of the multiples of median control values, MoM) in patients homozygous for the prevalent Hispanic mutation c.572C>T (p.T191M) but was highly elevated (2.95 MoM) in a single patient homozygous for the c.1330G>A (p.D444N) mutation. Patients with the remaining nine genotypes exhibited decreased activities (0.00-0.22 MoM), which did not overlap with the controls (0.29-2.10 MoM).

CONCLUSIONS

The determination of CBS activity in plasma is a rapid and non-invasive procedure for detecting a subgroup of CBS-deficient patients with distinct genotypes.

Для цитирования: Alcaide P, Krijt J, Ruiz-Sala P, Ješina P, Ugarte M, Kožich V, Merinero B. Enzymatic diagnosis of homocystinuria by determination of cystathionine-ß-synthase activity in plasma using LC-MS/MS.. Clinica chimica acta; international journal of clinical chemistry. 2014. DOI: 10.1016/j.cca.2014.09.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.