MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/iembs.2011.6091680

Медицинская библиотека · Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2011

Liquid cooling system for the vibro-tactile threshold device.

Parsons Erin M, Redd Christian, Gandhi Minu S, Tuckett Robert P, Bamberg Stacy J Morris

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

Vibrotactile threshold testing has been used to investigate activation of human somatosensory pathways. A portable vibrotactile threshold testing device called the Vibrotactile Threshold Evaluator for the Workplace (VTEW) was designed for screening of carpal tunnel syndrome in the workplace, and initially contained a small fan for cooling. During subject testing, the device is operated intermittently, which causes the linear actuator to warm the tactile probe. The probe causes discomfort for some subjects. During testing, the probe heated to 42 °C within 90 seconds of continuous operation. A liquid cooling system was implemented to dissipate heat from the probe. The liquid cooling system maintains a steady state temperature of 36 °C for continuous actuation of the probe. The liquid cooling system is capable of maintaining a safe operating temperature, without adding erroneous vibrations to the device. However, the cooling system deters the portability of the device. Further research will investigate how to make the liquid cooling system portable and implements vibrotactile threshold testing in the workplace to quickly evaluate whether or not a person has early symptoms of carpal tunnel syndrome.

Для цитирования: Parsons Erin M, Redd Christian, Gandhi Minu S, Tuckett Robert P, Bamberg Stacy J Morris. Liquid cooling system for the vibro-tactile threshold device.. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. 2011. DOI: 10.1109/iembs.2011.6091680.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.