MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11060-017-2423-y

Медицинская библиотека · Journal of neuro-oncology · 2017

Preoperative grading of supratentorial nonenhancing gliomas by high b-value diffusion-weighted 3 T magnetic resonance imaging.

Han Haiwei, Han Chengkun, Wu Xiurong, Zhong Shan, Zhuang Xiongjie, Tan Guowei, Wu Hua

СтатьяПеревод пока не подготовлен

Аннотация

The purpose of this study was to determine the difference in discrimination between high- and low-grade supratentorial nonenhancing gliomas (HGGs and LGGs, respectively) when using apparent diffusion coefficient (ADC) values with high or standard b-value. Thirty-nine patients underwent conventional magnetic resonance imaging and diffusion-weighted imaging (DWI) with standard and high b-values (b = 1000 and 3000 s/mm2, respectively). Minimum, maximum, and mean ADC values (ADCMIN, ADCMAX, and ADCMEAN, respectively) were measured from ADC maps with both b-values. Receiver operating curve analysis was used to determine the cutoff ADC values for distinguishing between nonenhancing HGGs and LGGs. ADCMIN, ADCMAX, and ADCMEAN values for the nonenhancing HGGs were lower than those for LGGs. These differences were much larger when a high b-value was used (all P < 0.0001) than when a standard b-value was used (P = 0.0001, <0.0001, and <0.0001, respectively). Discriminant analysis indicated that the greatest likelihood for discriminating HGGs and LGGs when ADCMEAN was obtained with a high b-value, with cutoff value of 0.814 × 10-3 mm2/s. ADC values obtained with a high b-value can be useful for grading and surgical management of nonenhancing HGGs and LGGs. The lowest degree of overlap was obtained when ADCMEAN was determined with a b-value of 3000 s/mm2.

Для цитирования: Han Haiwei, Han Chengkun, Wu Xiurong, Zhong Shan, Zhuang Xiongjie, Tan Guowei, Wu Hua. Preoperative grading of supratentorial nonenhancing gliomas by high b-value diffusion-weighted 3 T magnetic resonance imaging.. Journal of neuro-oncology. 2017. DOI: 10.1007/s11060-017-2423-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.