99mTc-HMPAO brain single photon emission computerized tomography in mitochondrial encephalomyopathies.

Yen T C, Yeh S H

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Mitochondrial encephalomyopathies are heterogeneous diseases with common clinical features of muscle and/or the central nervous system. Although molecular and histological diagnoses have been established, imaging modalities for the functioning evaluation of these patients are still obscure. In this study, we tried to use 99mTc-HMPAO brain SPECT images to analyze various mitochondrial encephalomyopathies.

METHODS

We examined 99mTc-HMPAO Brain SPECT studies of 15 patients with various types of mitochondrial encephalomyopathy (3 Leber's hereditary optic neuropathy (LHON), 4 Kearns-Sayre syndrome (KSS), 4 mitochondrial myopathy, encephalopathy, lactic acidosis, and stroke-like episodes (MELAS), 3 myoclonic epilepsy and ragged-red fiber disease (MERRF), and 1 Leigh syndrome), diagnosed by molecular studies.

RESULTS

The results of our studies show obviously decreased radiotracer accumulation in the parieto-temporal regions after stroke-like episodes in patients with MELAS and MERRF: Relatively diminished brain perfusion in patients with KSS is noted, probably secondary to severe encephalomyopathy or subdural effusion. However, there seems to be no significant correlation between the clinical manifestations and the imaging findings in LHON and Leigh.

CONCLUSIONS

99mTc-HMPAO Brain SPECT is useful in the diagnosing and assessment of the progress of MERRF, MELAS and KSS. However, its role in LHON and Leigh syndrome seems to be debatable.

Для цитирования: Yen T C, Yeh S H. 99mTc-HMPAO brain single photon emission computerized tomography in mitochondrial encephalomyopathies.. Zhonghua yi xue za zhi = Chinese medical journal; Free China ed. 1995.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.