MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d5ay01243k

Медицинская библиотека · Analytical methods : advancing methods and applications · 2025

An easy and sensitive approach to measure the binding parameters of metal ionic ligands and calcium sensing receptors in ion chromatography.

Han Yaokun, Shi Xiangang, Wang Pei, Xiao Chaoni

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Some G protein-coupled receptors (GPCRs) exert biological functions and pharmacological actions by interacting with metal ions directly and allosterically; however, it is not easy to measure the binding parameters between them to gain insights into their mechanisms of action. In this study, a mini separation column packed with calcium sensing receptor (CaSR) immobilized on solid matrix particles (9.37 mg CaSR per gram silica, 0.8 g) was prepared to reveal the binding action of metal ionic ligands in ion chromatography. The results of this study indicate that the CaSR-immobilized column could recognize different metal ions in the following order of affinities: Gd3+ > Ca2+ > Na+, affording association equilibrium constants and the total binding sites of the orthosteric ligands Ca2+ and Gd3+ and sensitively probing the binding affinities of the two metal ions in response to CaSR-targeted specific allosteric modulators. Molecular docking demonstrated that the larger binding affinity of Gd3+ than that of Ca2+ is attributable to the stronger electrostatic forces of Gd3+ with the residues ASN189, GLU191 and HIS192 of CaSR owing to the more positive charges. Unlike current methods, the CaSR-immobilized column represents an easy and sensitive approach to estimate the binding parameters of metal ions and GPCRs in solution using relatively small quantities of materials, providing important information about their mechanisms of action.

Для цитирования: Han Yaokun, Shi Xiangang, Wang Pei, Xiao Chaoni. An easy and sensitive approach to measure the binding parameters of metal ionic ligands and calcium sensing receptors in ion chromatography.. Analytical methods : advancing methods and applications. 2025. DOI: 10.1039/d5ay01243k.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.