DOI 10.1016/j.wneu.2015.11.036
Oblique Positioning of the Stereotactic Frame for Biopsies of Cerebellar and Brainstem Lesions.
Аннотация
BACKGROUND
Frame-based stereotactic biopsy has proven to be a safe procedure with a high diagnostic yield for patients. Different supratentorial localizations can easily be accessed by standardized stereotactic approaches. Cerebellar and brainstem lesions, however, are not easy to reach because the positioning of the frame pins often makes it impossible to address the entry point properly.
METHODS
By oblique positioning of the frame, cerebellar and brainstem lesions also can easily be accessed to take tissue samples.
CONCLUSION
Modification of the standardized positioning of the frame allows for safe and straightforward stereotactic access even to cerebellar and brainstem lesions.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.