DOI 10.1016/j.ijrobp.2021.09.004
International Multi-institutional Patterns of Contouring Practice and Clinical Target Volume Recommendations for Stereotactic Body Radiation Therapy for Non-Spine Bone Metastases.
Аннотация
PURPOSE: Despite the increasing use of stereotactic body radiation therapy for non-spine bone metastases (NSBM), there is no established standard for target delineation. The objective of this study was to provide consensus recommendations on clinical target volume (CTV) delineation based on international expert contours.
METHODS AND MATERIALS: Eleven cases of NSBM were contoured by 9 international radiation oncologists. For each case, the gross tumor volume was provided on the simulation computed tomography scans with accompanying magnetic resonance imaging. Participants contoured the CTV and completed a clinical survey. Agreement between CTV contours were analyzed with simultaneous truth and performance level estimation using the kappa coefficient and the Dice similarity coefficient (DSC) and summarized to establish contouring recommendations. A direction-dependent analysis was applied to the consensus contours to quantify margins.
RESULTS
All CTV contours were completed. Six participants used a single-dose level, whereas 3 used a 2-dose level simultaneous integrated boost (SIB) technique. For the SIB cases, the largest volume receiving a stereotactic body radiation therapy (SBRT) dose was used for contour analysis. There was substantial agreement between contours across cases with a mean kappa of 0.72 (mean sensitivity 0.85, mean specificity 0.97). The mean DSC value was 0.77 (range, 0.67-0.87). Consensus CTV contouring recommendations were (1) an intraosseous CTV margin of 5 to 10 mm should be strongly considered within contiguous bone; (2) an extraosseous margin of 5 to 10 mm should be strongly considered where there is soft tissue disease or cortical bone disruption; (3) CTVs should be manually cropped to respect anatomic barriers to spread (eg, peritoneal cavity, pleura, uninvolved joint space and cortical bone).
CONCLUSIONS
CTV contouring recommendations for NSBM-SBRT were established based on analysis of international expert consensus contours with a high level of agreement. These principles may provide guidance to treating physicians and inform future study until prospective clinical data can provide further refinement.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.