DOI 10.1021/am405774v

Медицинская библиотека · ACS applied materials & interfaces · 2014

Mussel inspired coating of a biocompatible cyclodextrin based polymer onto CoCr vascular stents.

Sobocinski Jonathan, Laure William, Taha Mariam, Courcot Elisabeth, Chai Feng, Simon Nicolas, Addad Ahmed, Martel Bernard, Haulon Stephan, Woisel Patrice, Blanchemain Nicolas, Lyskawa Joel

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

During the past decade, drug-eluting stents (DES) have been widely used for the treatment of occlusive coronary artery diseases. They are supposed to reduce the incidence of early in-stent restenosis by the elution of highly hydrophobic antiproliferative drugs. Nevertheless, the absence of long-term activity of these devices is responsible for late acute thrombosis probably due to the delayed re-endothelialization of the arterial wall over the bare metallic stent struts. Thus, a new generation of DES with a sustained release of therapeutic agents is required to improve long-term results of these devices. In this article, we report an original functionalization of CoCr vascular devices with a hydrophilic, biocompatible and biodegradable cyclodextrins based polymer which acts as a reservoir for lipophilic drugs allowing the sustained release of antiproliferative drugs. In this setting, polydopamine (PDA), a strong adhesive biopolymer, was applied as a first coating layer onto the surface of the metallic CoCr device in order to promote the strong anchorage of a cyclodextrin polymer. This polymer was generated "in situ" from the methylated cyclodextrins and citric acid as a cross-linking agent through a polycondensation reaction. After optimization of the grafting process, the amount of cyclodextrin polymer coated onto the CoCr device was quantified by colorimetric titrations and the resulting film was characterized by scanning electron microscopy (SEM) investigations. The cytocompatibility of the resulting coated film was assessed by cell proliferation and vitality tests. Finally, the ability of this coated device to act as a drug-eluting system was evaluated with paclitaxel, a strong hydrophobic antiproliferative drug, a reference drug used in current vascular drug-eluting stents.

Для цитирования: Sobocinski Jonathan, Laure William, Taha Mariam, Courcot Elisabeth, Chai Feng, Simon Nicolas, Addad Ahmed, Martel Bernard, Haulon Stephan, Woisel Patrice, Blanchemain Nicolas, Lyskawa Joel. Mussel inspired coating of a biocompatible cyclodextrin based polymer onto CoCr vascular stents.. ACS applied materials & interfaces. 2014. DOI: 10.1021/am405774v.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.