Journal of neural engineering · 2026
Integrated neuronavigation and acoustic-thermal modeling for simultaneous transcranial ultrasound stimulation (TUS) and functional MRI.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Jeong Moon, Zadeh Ali K, Coreas Alan, Girgis Fady, Pichardo Samuel, Pike G Bruce
Аннотация
Objective. We present and validate an integrated workflow for accurate and stable targeting of a TUS transducer inside the MRI scanner using subject-specific imaging, neuronavigation, acoustic-thermal modeling, transducer positioning and fixation, and in-scanner verification.Approach. A stimulation target was defined in the left primary motor cortex (M1) hand knob using structural imaging and task-based functional magnetic resonance imaging (fMRI) collected during a planning session, then transferred to neuronavigation for trajectory planning and scalp marking. Acoustic and thermal simulations characterized the acoustic beam geometry and adjusted ultrasound power to achieve the desired acoustic field at the target within safety constraints. During the experiment scanning session, low-resolutionT1-weighted localizer images visualized transducer fiducials and the planned target directly on the scanner console, enabling iterative in-bore refinement.Main results. Coupled with a custom MRI-compatible transducer fixation cap enabling controlled multi-axis adjustments, this workflow achieved a mean post-refinement off-target distance of 1.41.0 mm across five participants over 19 sessions, falling within one fMRI voxel (2.5 mm) of the planned target in 17 of 19 sessions (89%). Repeat transducer position verification approximately 40 min after initial setup showed minimal positional drift (0.2 mm). In an expanded cohort of 12 participants with balanced sex distribution (six males, six females), mean post-adjustment off-target distance was 2.180.78 mm in males and 1.930.69 mm in females, with comparable performance between sexes (Mann-Whitney U = 22; descriptive), and an overall success rate of nine of 12 sessions (75%). fMRI tSNR in M1 was preserved with the passive transducer (left-to-right M1 ratio 0.900.12) and during active sonication (0.900.09) across the same 12 participants, indicating that the 20 mm coupling gel pad effectively mitigated susceptibility-related signal dropout and that active sonication introduced no additional signal degradation.Significance. This workflow provides a practical experimental foundation for in-scanner targeting and verification for simultaneous human TUS-fMRI studies, with MRI signal quality preserved during active sonication and consistent targeting performance across male and female participants.