PloS one · 2019
Cognitive performance and brain dynamics during walking with a novel bionic foot: A pilot study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
De Pauw Kevin, Cherelle Pierre, Tassignon Bruno, Van Cutsem Jeroen, Roelands Bart, Marulanda Felipe Gomez, Lefeber Dirk, Vanderborght Bram, Meeusen Romain
Аннотация
OBJECTIVES: The objectives are to determine neural dynamics during gait using electro-encephalography and source localization, and to investigate the attentional demand during walking in able-bodied individuals, and individuals with an amputation.
MATERIALS & METHODS: Six able-bodied individuals conducted one experimental trial, and 6 unilateral transtibial and 6 unilateral transfemoral amputees performed 2 experimental trials; the first with the prosthesis currently used by the subjects and the second with a novel powered transtibial prosthesis, i.e. the Ankle Mimicking Prosthetic foot 4.0. Each experimental trial comprised 2 walking tasks; 6 and 2 minutes treadmill walking at normal speed interspersed by 5 minutes of rest. During 6 minutes walking the Sustained Attention to Response (go-no go) Task, which measures reaction time and accuracy, was performed. Electro-encephalographic data were gathered when subjects walked 2 minutes. Motor-related cortical potentials and brain source activity during gait were examined. Normality and (non-) parametric tests were conducted (p<0.05).
RESULTS AND DISCUSSION: In contrast to transtibial amputees, transfemoral amputees required more attentional demands during walking with Ankle Mimicking Prosthetic foot 4.0 compared to the current passive prosthetic device and able-bodied individuals (reaction time and accuracy: p≤0.028). Since risk of falling is associated with altered attentional demands, propulsive forces of the novel device need to be better controlled for transfemoral amputees. No motor-related cortical potentials at Cz were observed in transfemoral amputees walking with the novel prosthesis, whereas motor-related cortical potentials between transtibial amputees and able-bodied individuals during walking at normal speed did not differ. The first positive electro-physiological peak deflection appeared during toe-off phase and showed higher activity within the underlying brain sources in transtibial amputees walking with Ankle Mimicking Prosthetic foot 4.0 compared to able-bodied individuals. The required higher neural input to accomplish the same physical activity compared to able-bodied individuals is possibly due to the limited acclimation period to the novel device and consequently increased afferent sensory feedback for postural control.
MATERIALS & METHODS: Six able-bodied individuals conducted one experimental trial, and 6 unilateral transtibial and 6 unilateral transfemoral amputees performed 2 experimental trials; the first with the prosthesis currently used by the subjects and the second with a novel powered transtibial prosthesis, i.e. the Ankle Mimicking Prosthetic foot 4.0. Each experimental trial comprised 2 walking tasks; 6 and 2 minutes treadmill walking at normal speed interspersed by 5 minutes of rest. During 6 minutes walking the Sustained Attention to Response (go-no go) Task, which measures reaction time and accuracy, was performed. Electro-encephalographic data were gathered when subjects walked 2 minutes. Motor-related cortical potentials and brain source activity during gait were examined. Normality and (non-) parametric tests were conducted (p<0.05).
RESULTS AND DISCUSSION: In contrast to transtibial amputees, transfemoral amputees required more attentional demands during walking with Ankle Mimicking Prosthetic foot 4.0 compared to the current passive prosthetic device and able-bodied individuals (reaction time and accuracy: p≤0.028). Since risk of falling is associated with altered attentional demands, propulsive forces of the novel device need to be better controlled for transfemoral amputees. No motor-related cortical potentials at Cz were observed in transfemoral amputees walking with the novel prosthesis, whereas motor-related cortical potentials between transtibial amputees and able-bodied individuals during walking at normal speed did not differ. The first positive electro-physiological peak deflection appeared during toe-off phase and showed higher activity within the underlying brain sources in transtibial amputees walking with Ankle Mimicking Prosthetic foot 4.0 compared to able-bodied individuals. The required higher neural input to accomplish the same physical activity compared to able-bodied individuals is possibly due to the limited acclimation period to the novel device and consequently increased afferent sensory feedback for postural control.