MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/14992027.2012.712721

Медицинская библиотека · International journal of audiology · 2012

Audiological and radiological characteristics of a family with T961G mitochondrial mutation.

Turchetta Rosaria, Mazzei Filippo, Celani Tiziana, Cammeresi Maria Gloria, Orlando Maria Patrizia, Altissimi Giancarlo, de Vincentiis Chiara, D'Ambrosio Ferdinando, Messineo Daniela, Ferraris Alessandro, Cianfrone Giancarlo

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The aim of this study was to describe audiological and radiological characteristics, and other secondary aspects, in a family carrying a T961G mutation in the 12S rRNA mitochondrial gene.

DESIGN

Case report.

STUDY SAMPLE: Six members of a family participated in an audiological evaluation that included pure-tone audiometry, immittance tests, auditory brainstem responses (ABR), and otoacoustic emissions (OAE). The radiological evaluation was conducted through temporal bone CT scans using a Toshiba 16 channels Aquilon Spirale. Neuropsychiatric evaluation was also administered.

RESULTS

Three participants were diagnosed with severe sensorineural hearing loss of cochlear origin and cochlear malformations visible in CT scans. One participant had a mild mixed-hearing loss and no cochlear malformations. Two participants had normal audiological and radiological findings.

CONCLUSIONS

We believe our study can provide helpful insight on the clinical findings of a rare mutation, of which few data have been presented in literature.

Для цитирования: Turchetta Rosaria, Mazzei Filippo, Celani Tiziana, Cammeresi Maria Gloria, Orlando Maria Patrizia, Altissimi Giancarlo, de Vincentiis Chiara, D'Ambrosio Ferdinando, Messineo Daniela, Ferraris Alessandro, Cianfrone Giancarlo. Audiological and radiological characteristics of a family with T961G mitochondrial mutation.. International journal of audiology. 2012. DOI: 10.3109/14992027.2012.712721.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.