MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1044/2025_aja-24-00259

Медицинская библиотека · American journal of audiology · 2025

Audiological Parameters and Musical Perception in Cochlear Implant Users: Traditional Versus Anatomy-Based Fittings of OTOPLAN.

Deniz Hüseyin, Ataş Ahmet, Kara Eyyüp

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: The aim of this prospective study was to compare the results of the traditional cochlear implant fitting method and the anatomy-based fitting method.

METHOD: Seventy-two cochlear implant users with congenital (36 participants) and postlingual (36 participants) profound hearing loss and unilateral cochlear implantation were included in the study. After determining the center frequencies according to the actual anatomical location of each electrode contact on the computed tomography records obtained after implantation with OTOPLAN software (Version 1.5.0; CAScination AG), the cochlear implant processor was programmed with MED-EL MAESTRO 9.0 software using an anatomy-based fitting method. The Musical Perception Test (MPT), Spectral-Temporally Modulated Ripple Test (SMRT), free-field pure-tone hearing thresholds, speech recognition, and speech discrimination tests were applied. The results obtained with both methods were compared.

RESULTS

In both groups, the MPT and SMRT scores, free-field pure-tone hearing thresholds with cochlear implants, speech recognition, and speech discrimination test results were significantly higher with the anatomy-based fitting method compared with the traditional fitting method (p < .05).

CONCLUSIONS

Cochlear implant users performed better with anatomy-based fitting. Thus, anatomy-based fitting should be incorporated into cochlear implant speech processor fitting methods.

Для цитирования: Deniz Hüseyin, Ataş Ahmet, Kara Eyyüp. Audiological Parameters and Musical Perception in Cochlear Implant Users: Traditional Versus Anatomy-Based Fittings of OTOPLAN.. American journal of audiology. 2025. DOI: 10.1044/2025_aja-24-00259.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.