MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11282-020-00439-w

Медицинская библиотека · Oral radiology · 2020

Radiation dosimetry analyses of radiographic imaging systems used for orthodontic treatment: comparison among child, adolescent, and adult patients.

Lee Kuk Sun, Nam Ok Hyung, Kim Gyu-Tae, Choi Sung Chul, Choi Yong-Suk, Hwang Eui-Hwan

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was to compare the effective doses of orthodontic radiographs in children, adolescents, and adults.

METHODS

We exposed a child, an adolescent (simulated by an adult female phantom), and adult male phantoms using common scanning protocols for panoramic radiography, cephalography, and cone-beam computed tomography (CBCT). Glass dosimeters were placed in the organs of the phantom to measure the absorbed doses. The effective doses were deduced using tissue weighting factors as defined in the ICRP Publication 103.

RESULTS

For panoramic imaging, the parotid gland had the highest absorbed dose in the child and the submandibular glands had the highest absorbed dose in both the adolescent and adult phantoms. For cephalography, the organs and tissues located closest to the X-ray tube had the highest absorbed dose values. For CBCT, the lenses of the eyes received the highest absorbed dose. Effective doses with CBCT were the greatest in the adolescent phantom, followed by in the adult and child phantoms.

CONCLUSIONS

Dental practitioners should be aware of patient age, as younger patients will incur greater risks from radiation.

Для цитирования: Lee Kuk Sun, Nam Ok Hyung, Kim Gyu-Tae, Choi Sung Chul, Choi Yong-Suk, Hwang Eui-Hwan. Radiation dosimetry analyses of radiographic imaging systems used for orthodontic treatment: comparison among child, adolescent, and adult patients.. Oral radiology. 2020. DOI: 10.1007/s11282-020-00439-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.