Individual computer-assisted 3D planning for surgical placement of a new bone conduction hearing device.

Plontke Stefan K, Radetzki Florian, Seiwerth Ingmar, Herzog Michael, Brandt Silvio, Delank Karl-Stefan, Rahne Torsten

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the benefit of a preoperative three-dimensional (3D) planning tool for surgically placing the bone conduction floating mass transducer (BC-FMT) of the Bonebridge (BB) bone conduction implant.

PATIENTS: Adult patients (n = 5) and one pediatric patient (n = 1) with conductive or mixed hearing loss caused by chronic ear disease, malformation, or single-sided deafness.

INTERVENTION(S): Development of a preoperative planning tool that allowed free adjustment of the implant in an individual 3D model of the skull to evaluate completely fitting the BC-FMT into a bony bed and to identify an optimal implant position. Implantation of the BB with mastoid or retrosigmoid placement after individual preoperative planning and "virtual surgery".

MAIN OUTCOME MEASURES: Feasibility of the preoperative 3D planning process, transfer into the intraoperative situation, and audiologic results after BB implantation.

RESULTS

Individual preoperative planning was considered beneficial especially in cases of small mastoid bone volume, for example, because of previous canal wall down mastoidectomies, and in the case with malformation.

CONCLUSION

For optimal placement of the BC-FMT of the BB, preoperative 3D planning is recommended especially in primarily small poorly pneumatized mastoids, hypoplastic mastoids in malformations, reduced bone volume after canal wall down mastoidectomy, or the small mastoids in children. Effort should be made to reduce segmentation and surgical planning time by means of automation.

Для цитирования: Plontke Stefan K, Radetzki Florian, Seiwerth Ingmar, Herzog Michael, Brandt Silvio, Delank Karl-Stefan, Rahne Torsten. Individual computer-assisted 3D planning for surgical placement of a new bone conduction hearing device.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2014. DOI: 10.1097/mao.0000000000000405.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.