MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jos.2018.12.007

Медицинская библиотека · Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association · 2019

Application of a peripheral vein illumination device to reduce saphenous structure injury caused by screw insertion during arthroscopic ankle arthrodesis.

Nakasa Tomoyuki, Ikuta Yasunari, Tsuyuguchi Yusuke, Ota Yuki, Kanemitsu Munekazu, Adachi Nobuo

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Arthroscopic ankle arthrodesis (AAA) is minimally invasive surgery, whereby percutaneous screw fixation is used through the medial aspect of the distal tibia to fusion the ankle, but it carries the risk of the saphenous vein and nerve injuries. The near-infrared (NIR) vascular imaging system, the VeinViewer® Flex, projects an image of the vein onto the skin, and the visualization of the vein may reduce the vein and nerve injuries. The purpose of this study is to investigate the risk of the saphenous vein injury by the percutaneous screw insertion during AAA, and to evaluate the effectiveness of the NIR vascular imaging system in the reduction of the saphenous vein injury.

METHODS

Ten patients with the ankle osteoarthritis underwent AAA. Three screw insertion sites (proximal as number 1, anterior distal as number 2, and posterior distal as number 3) were marked and then the vein was depicted on the medial malleolus using the VeinViewer® Flex. The distance between the screw insertion sites and the closest vein was measured. Additionally, the pattern of the vein course on the medial aspect of the distal tibia was investigated in 32 ankles using the VeinViewer® Flex.

RESULTS

The distance of number 1, 2, and 3 from the vein was 2.4 ± 1.4 mm (range from 0 to 5 mm), 6.3 ± 6.6 mm (range from 0 to 20 mm) and 3.5 ± 3.1 mm (range from 0 to 11 mm) respectively. In anterior screw insertion site, 3 of 10 cases showed just on the vein. The veins were observed at the anterior region from the center axis of the tibia more than 75% of ankles which was suspected as the greater saphenous vein with closely running of the saphenous nerve, but also other regions had the crossing vein.

CONCLUSIONS

Percutaneous screw fixation during AAA runs the risk of causing the saphenous structure injury. The NIR light imaging system is beneficial in reducing the complications of saphenous structure damage in AAA.

Для цитирования: Nakasa Tomoyuki, Ikuta Yasunari, Tsuyuguchi Yusuke, Ota Yuki, Kanemitsu Munekazu, Adachi Nobuo. Application of a peripheral vein illumination device to reduce saphenous structure injury caused by screw insertion during arthroscopic ankle arthrodesis.. Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association. 2019. DOI: 10.1016/j.jos.2018.12.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.