DOI 10.1227/neu.0b013e31823f5ade
Predictive value and safety of intraoperative neurophysiological monitoring with motor evoked potentials in glioma surgery.
Аннотация
BACKGROUND
Resection of gliomas in or adjacent to the motor system is widely performed with intraoperative neuromonitoring (IOM). Despite the fact that data on the safety of IOM are available, the significance and predictive value of the procedure are still under discussion. Moreover, cases of false-negative monitoring affect the surgeon's confidence in IOM.
OBJECTIVE
To examine cases of false-negative IOM to reveal structural explanations.
METHODS
Between 2007 and 2010, we resected 115 consecutive supratentorial gliomas in or close to eloquent motor areas using direct cortical stimulation for monitoring of motor evoked potentials (MEPs). The monitoring data were reviewed and related to new postoperative motor deficit and postoperative imaging. Clinical outcomes were assessed during follow-up.
RESULTS
Monitoring of MEPs was successful in 112 cases (97.4%). Postoperatively, 30.3% of patients had a new motor deficit, which remained permanent in 12.5%. Progression-free follow-up was 9.7 months (range, 2 weeks-40.6 months). In 65.2% of all cases, MEPs were stable throughout the operation, but 8.9% showed a new temporary motor deficit, whereas 4.5% (5 patients) presented with permanently deteriorated motor function representing false-negative monitoring at first glance. However, these cases were caused by secondary hemorrhage, ischemia, or resection of the supplementary motor area.
CONCLUSION
Continuous MEP monitoring provides reliable monitoring of the motor system, influences the course of operation in some cases, and has to be regarded as the standard for IOM of the motor system. In our series, we found no false-negative MEP results.