MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00056-016-0071-z

Медицинская библиотека · Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie · 2016

Effects of two different removable functional appliances on depth of the posterior airway space : A retrospective cephalometric study.

Hourfar Jan, Kinzinger Gero Stefan Michael, Meißner Luisa Katharina, Lisson Jörg Alexander

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Aim of the study was the comparison of treatment effects upon pharyngeal depth in patients treated with either (1) S-II-appliance or (2) Activator.

METHODS

Pre- and posttreatment lateral cephalograms of 73 patients were analyzed using a customized set of measurements. According to predefined criteria, patients were either treated with S-II-appliance or Activator. Pharyngeal depth was assessed from cranial to caudal at six levels (P1 to P6). Paired t tests were used for intragroup and t tests for independent samples for intergroup comparisons. Results were considered statistically significant at p ≤ 0.05.

RESULTS

37 (22 female, 15 male) patients were treated with the S-II-appliance (mean pretreatment age 11.1 ± 1.07 years), and 36 (20 female, 16 male) patients with an Activator (mean pretreatment age 11.3 ± 1.12 years). Mean treatment time was 14 months for the S-II-appliance and 12 months for the Activator. Most measurements at the different levels showed an average increase ranging from approximately 0.5 mm to almost 2 mm. Changes were more pronounced in S-II patients. In contrast to intergroup comparisons, some intragroup comparisons revealed statistically significant differences at levels P5 (p = 0.0062) and P6 (p = 0.0155) in S-II patients and at P1-level (p = 0.0197) in Activator patients.

CONCLUSIONS

Both appliances similarly led to an increase of the pharyngeal depth. The sites of statistically significant changes differed.

Для цитирования: Hourfar Jan, Kinzinger Gero Stefan Michael, Meißner Luisa Katharina, Lisson Jörg Alexander. Effects of two different removable functional appliances on depth of the posterior airway space : A retrospective cephalometric study.. Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie. 2016. DOI: 10.1007/s00056-016-0071-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.