MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40510-015-0073-1

Медицинская библиотека · Progress in orthodontics · 2015

Cephalometric study to test the reliability of anteroposterior skeletal discrepancy indicators using the twin block appliance.

Trivedi Rahul, Bhattacharya Amit, Mehta Falguni, Patel Dolly, Parekh Harshik, Gandhi Vaibhav

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The objectives of this study were to check the reliability of the five angular and two linear parameters for sagittal maxillo-mandibular discrepancy and to compare and correlate angular parameters with the ANB angle, and the linear parameter with Wits analysis.

METHODS

The pre-treatment and post-functional lateral cephalograms of 25 subjects (17 males, 8 females) with class II division 1 malocclusion treated with twin block functional appliance were selected. Five angular (ANB, β angle, APDI, YEN angle, W angle) and two linear (Wits analysis, App-Bpp) parameters were traced on both sets of cephalograms. Paired Student's t-test, one-way ANOVA, post hoc test, and Karl Pearson correlation statistical analysis were performed.

RESULTS

All the parameters considered in our study showed highly significant difference in pre-treatment and post-functional values, suggesting their reliability (p < 0.0001). When ANB angle was compared with the other angular parameters, a highly significant change in the mean value of the difference in pre-treatment (T1) and post-functional (T2) values was noted (p < 0.001). No significant change was seen when comparing the mean value of the difference in T1 and T2 between linear parameters (p = 0.949).

CONCLUSIONS

All the parameters used in the study can be reliably used to assess anteroposterior skeletal discrepancy. Whenever limitations of the ANB angle and Wits analysis are foreseen, the W angle and App-Bpp, respectively, can be reliably used. The YEN angle may reliably predict the post-functional change with the use of twin block appliance.

Для цитирования: Trivedi Rahul, Bhattacharya Amit, Mehta Falguni, Patel Dolly, Parekh Harshik, Gandhi Vaibhav. Cephalometric study to test the reliability of anteroposterior skeletal discrepancy indicators using the twin block appliance.. Progress in orthodontics. 2015. DOI: 10.1186/s40510-015-0073-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.