Gosal Jaskaran S, Bhuskute Govind S, Alsavaf Mohammad Bilal, Abouammo Moataz D, Manjila Sunil, Alwabili Mohammed, Wu Kyle C, Jha Deepak K, Carrau Ricardo L, Prevedello Daniel M

Аннотация

OBJECTIVE: Accessing the petrous apex (PA) via an endoscopic endonasal approach (EEA) is challenging due to its posterior and lateral anatomical relationship with the paraclival carotid artery. Typically, the EEA requires the mobilization or compression of the vessel and the use of angled-lens endoscopes and instruments. A sublabial contralateral transmaxillary (CTM) corridor has been used to overcome these challenges. Still, it requires extensive osteo-meatal disruption and drilling of the medial pterygoid process, which risks the vidian nerve and increases nasal morbidity. Furthermore, the CTM corridor positions the endoscope in the same horizontal plane as the instruments passing through the nostrils, leading to fencing. The authors propose a novel minimally invasive route to the PA, the precaruncular contralateral medial transorbital (cMTO) corridor, to address these issues. This anatomical study compares the EEA+CTM and EEA+cMTO corridors in accessing the PA.

METHODS: The authors dissected 14 fresh, preinjected cadaveric specimens (28 sides) using neuronavigation to complete EEA, cMTO, and CTM on each side. In addition to qualitative analysis, they measured and compared the working distance between the entry point (nose, orbit, maxilla) and the petrosal process of the sphenoid bone (PPSB), superomedial PA, and foramen lacerum (FL); angle of attack (AoA); area of surgical freedom; endoscope-instrument fencing angle; and visual angle for each approach.

RESULTS: The cMTO corridor provided the shortest working distance to the petroclival region (PA = 67.4 ± 4.47 mm, PPSB = 67.57 ± 4.33 mm, and FL = 66.30 ± 4.77 mm) compared to the CTM (PA = 75.85 ± 3.63 mm, PPSB = 76 ± 3.96 mm, and FL = 74.52 ± 4.26 mm) and to the EEA (PA = 85.16 ± 3.16 mm, PPSB = 84.55 ± 3.02 mm, and FL = 83.42 ± 3.21 mm, p < 0.001). Both CTM and cMTO corridors had a similar visual angle to the PA (20.72° ± 2.16° and 21.63° ± 1.84°, respectively), offering a similar but significantly better visualization than EEA alone (44.71° ± 3.24°, p < 0.001). The cMTO corridor provided better instrument maneuverability than the CTM, as evidenced by a significantly greater fencing angle (30.9° ± 4.9°) than with the CTM (21.7° ± 4.02°, p < 0.001). The vertical AoAs for the EEA, cMTO, and CTM corridors were 9.79° ± 1.75°, 10.65° ± 0.82°, and 9.82° ± 1.43°, respectively (p = 0.009), whereas in the horizontal plane, these were 9.29° ± 1.51°, 9.10° ± 0.73°, and 10.49° ± 1.43° (p < 0.001), respectively. Both the CTM and cMTO corridors offered similar areas of surgical freedom (678.06 ± 99.5 mm2 and 673.59 ± 104.8 mm2, p = 0.986), but they were more significant than that provided by the EEA 487.29 ± 112.9 mm2 (p < 0.001).

CONCLUSIONS: The EEA+cMTO multiport technique may be a better alternative than the EEA+CTM multiport approach for targeting the petroclival region. However, clinical validation is required to confirm these laboratory findings.