DOI 10.1016/s0378-5955(00)00028-9
Discharge rate of the auditory nerve during noise revealed by electrocochlear stimulation.
Аннотация
The purpose of this study was to evaluate the average discharge rate of all fibres in the whole auditory nerve (R(wn)) when a broad-band noise with steady-state effects is applied to the ear. We assessed the R(wn) parameter by detecting the state of refractoriness of the nerve during noise stimulation using an electric stimulus (ES) as a probe. The technique, applied in awake pre-implanted guinea pigs (Charlet de Sauvage et al., 1994), made it possible to obtain electro-acoustic responses (EARs), from which an estimate of the R(wn) parameter could be deduced. Negative current pulses of 100 micros duration, each followed by an identical pulse of positive polarity for charge balance, were applied between round window and indifferent vertex electrodes at intervals of 160 ms. The 120 ms wide-band noise masker started 92 ms before every other negative ES. The signal on the stimulating electrodes was averaged over a 5.12 ms window in synchrony with the negative pulse. EARs were obtained by alternately subtracting recordings during noise from those during silence. The R(wn) parameter was determined by comparing experimental and computed EAR patterns. For this purpose, a model of unit response incorporating changes in amplitude and conduction velocity during the relative refractory period was designed. The recovery function of the firing probability in response to ES was evaluated. Fibres were classified in different categories according to their background discharge rates. The probability of response of single fibres to ES in each category was calculated on the basis of their interval histograms during silence and noise. Individual spikes were combined accordingly to obtain the computed EAR waveform. R(wn) was determined by adjusting the EAR amplitude of the model in relation to that of the experimental EAR. R(wn) generally increases in a linear fashion with respect to noise intensity expressed in dB, thus following the increase in loudness perception estimated by Weber's law. At the highest noise levels, R(wn) tends to saturate. The estimated saturation rate was found to be about 380 spikes/s.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.