MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mao.0000000000001845

Медицинская библиотека · Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2018

Successful Cochlear Implantation of a Split Electrode Array in a Patient With Far-advanced Otosclerosis Assisted by Electromagnetic Navigation: A Case Report.

Dejaco Daniel, Prejban David, Fischer Natalie, Freysinger Wolfgang, Stephan Kurt, Seebacher Josef, Widmann Gerlig, Riechelmann Herbert, Schmutzhard Joachim

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Incomplete electrode insertion is frequent when implanting ossified cochleae with conventional linear electrodes. If split electrode arrays (SEA) are used, this complication occurs less frequently resulting in improved audiological performance (AP). Additional implementation of electromagnetic navigation systems (EMNS) may add additional safety to this procedure and may further improve AP. However, previously performed SEA cochlea implantations rarely implemented EMNS. The few cases reported a laborious approach with customized, three-dimensional-printed microstereotactic headframes, which limited clinical feasibility. Moreover, no postoperative AP was reported. In this case report a more feasible approach, using a commercially available EMNS, is described and postoperative AP is reported.

PATIENT: A 70-year-old man with far-advanced otosclerosis was referred because of unsatisfactory speech intelligibility (monosyllabic word score of 0% at 75 dB sound pressure level) after cochlear implantation of a conventional linear electrode. Preoperative computed tomography revealed subtotal cochlear ossification and incomplete electrode insertion.

INTERVENTION: Four titanium screws were inserted into the petrous bone for computed tomography-based registration using an EMNS. The previous mastoidectomy was expanded, the misplaced conventional linear electrode extracted and a manual, free-handed superior cochleostomy at the level of the tendon of the tensor tympani muscle was performed. The location and course of the drill-out procedure for the SEA was planned and verified with EMNS.

RESULTS

Full electrode insertion for both electrode arrays of the SEA was achieved without any nerve dysfunction. Monosyllabic word score, determined 207 days after surgery, improved to 50 and 60% at 65 and 75 dB sound pressure level respectively.

CONCLUSION

The implementation of EMNS in SEA cochlear implantation added additional safety to the procedure, which resulted in full electrode insertion and superior AP. Yet, outcome in cochlear implantation may vary. Larger case series to confirm this observation are required. The approach proposed for EMNS-guided SEA in this case report, using commercially available EMNS, may lead to a more frequent implementation in clinical routine due to its good clinical feasibility. Thus, larger case series may be generated.

Для цитирования: Dejaco Daniel, Prejban David, Fischer Natalie, Freysinger Wolfgang, Stephan Kurt, Seebacher Josef, Widmann Gerlig, Riechelmann Herbert, Schmutzhard Joachim. Successful Cochlear Implantation of a Split Electrode Array in a Patient With Far-advanced Otosclerosis Assisted by Electromagnetic Navigation: A Case Report.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2018. DOI: 10.1097/mao.0000000000001845.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.