BACKGROUND

Cerebral near-infrared spectroscopy is a non-invasive tool used to measure regional cerebral tissue oxygenation (rScO2) initially validated in adult and pediatric populations. Preterm neonates, vulnerable to neurologic injury, are attractive candidates for NIRS monitoring; however, normative data and the brain regions measured by the current technology have not yet been established for this population.

METHODS

This study's aim was to analyze continuous rScO2 readings within the first 6-72 h after birth in 60 neonates without intracerebral hemorrhage born at ≤1250 g and/or ≤30 weeks' gestational age (GA) to better understand the role of head circumference (HC) and brain regions measured.

RESULTS

Using a standardized brain MRI atlas, we determined that rScO2 in infants with smaller HCs likely measures the ventricular spaces. GA is linearly correlated, and HC is non-linearly correlated, with rScO2 readings. For HC, we infer that rScO2 is lower in infants with smaller HCs due to measuring the ventricular spaces, with values increasing in the smallest HCs as the deep cerebral structures are reached.

CONCLUSION

Clinicians should be aware that in preterm infants with small HCs, rScO2 displayed may reflect readings from the ventricular spaces and deep cerebral tissue.

IMPACT: Clinicians should be aware that in preterm infants with small head circumferences, cerebral near-infrared spectroscopy readings of rScO2 displayed may reflect readings from the ventricular spaces and deep cerebral tissue. This highlights the importance of rigorously re-validating technologies before extrapolating them to different populations. Standard rScO2 trajectories should only be established after determining whether the mathematical models used in NIRS equipment are appropriate in premature infants and the brain region(s) NIRS sensors captures in this population, including the influence of both gestational age and head circumference.

Для цитирования: Kolnik Sarah E, Marquard Rebecca, Brandon Olivia, Puia-Dumitrescu Mihai, Valentine Gregory, Law Janessa B, Natarajan Niranjana, Dighe Manjiri, Mourad Pierre D, Wood Thomas R, Mietzsch Ulrike. Preterm infants variability in cerebral near-infrared spectroscopy measurements in the first 72-h after birth.. Pediatric research. 2023. DOI: 10.1038/s41390-023-02618-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.