Effect of mastoid drilling on hearing of the contralateral ear.
Аннотация
OBJECTIVES
This study aimed to: understand the effect that high intensity noise associated with drilling (during otological surgery) has on hearing in the contralateral ear; determine the nature of hearing loss, if any, by establishing whether it is temporary or persistent; and examine the association between hearing loss and various drill parameters.
METHODS
A prospective clinical study was carried out at a tertiary centre. Thirty patients with unilateral cholesteatoma and normal contralateral hearing were included. Patients were evaluated pre-operatively and for five days following surgery using high frequency pure tone audiometry, and low and high frequency transient evoked and distortion product otoacoustic emission testing.
RESULTS
The findings revealed statistically significant changes in distortion product otoacoustic emissions at high frequencies (p = 0.016), and in transient evoked otoacoustic emissions at both low and high frequencies (p = 0.035 and 0.021, respectively). There was a higher statistical association between otoacoustic emission changes and cutting burrs compared with diamond burrs.
CONCLUSION
Drilling during mastoid surgery poses a threat to hearing in the contralateral ear due to noise and vibration conducted transcranially.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.