MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mao.0b013e31826a52c7

Медицинская библиотека · Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2012

The round window: is it the "cochleostomy" of choice? Experience in 130 consecutive cochlear implants.

Gudis David A, Montes Michelle, Bigelow Douglas C, Ruckenstein Michael J

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To demonstrate that the round window insertion (RWI) for cochlear implantation with multichannel electrodes is a reliable, safe, and effective technique.

STUDY

DESIGN

Retrospective case review.

SETTING

Academic tertiary referral center.

PATIENTS: One hundred thirty consecutive cochlear implants (72 female and 58 male subjects) performed from August 2009 to August 2011. Devices included 83 Cochlear, 40 Med El, and 7 Advanced Bionics (AB) cochlear implants.

INTERVENTION: Subsequent to a full audiometric assessment, patients underwent a mastoidectomy with facial recess approach whereby the primary surgical objective was to perform a RWI. When the surgeon was unable to access the round window safely, a cochleostomy was performed anterior and inferior to the round window. Postoperative performance was measured with Hearing in Noise Test, the Consonant-Nucleus-Consonant test, and/or the Arizona Biomedical Sentences test.

MAIN OUTCOME MEASURES: Surgical feasibility of reliably performing a RWI, reason for cochleostomy, postoperative complications, and audiometric performance.

RESULTS

In 111 (85.4%) of 130 procedures, a RWI was performed; in 19 (14.6%), a cochleostomy was readily performed by the same approach. Reasons for creating a cochleostomy included facial nerve and jugular bulb location. There were no major postoperative complications in either group and 13 total minor complications. There was no statistically significant difference in postoperative complications or in audiometric performance between the 2 groups.

CONCLUSION

The RWI may offer several advantages over a cochleostomy, and it seems to be a reliable, safe, and effective technique for cochlear implantation with today's cochlear implant electrodes. Further studies would be necessary to verify these findings for broad application to the cochlear implant patient population.

Для цитирования: Gudis David A, Montes Michelle, Bigelow Douglas C, Ruckenstein Michael J. The round window: is it the "cochleostomy" of choice? Experience in 130 consecutive cochlear implants.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2012. DOI: 10.1097/mao.0b013e31826a52c7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.