DOI 10.1038/s41598-022-13891-x

Медицинская библиотека · Scientific reports · 2022

Comparison of three validated systems to analyse spinal shape and motion.

Dreischarf Bettina, Koch Esther, Dreischarf Marcel, Schmidt Hendrik, Pumberger Matthias, Becker Luis

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The assessment of spinal shape and mobility is of great importance for long-term therapy evaluation. As frequent radiation should be avoided, especially in children, non-invasive measurements have gained increasing importance. Their comparability between each other however stays elusive. Three non-invasive measurement tools have been compared to each other: Idiag M360, raster stereography and Epionics SPINE. 30 volunteers (15 females/15 males) have each been assessed by each system, investigating lumbar lordosis, thoracic kyphosis and spinal range-of-motion in the sagittal plane. Lumbar lordosis differed significantly (p < 0.001) between measurement devices but correlated significant to each other (Pearson's r 0.5-0.6). Regarding thoracic kyphosis no significant difference and a high correlation (r = 0.8) could be shown between Idiag M360 and raster stereography. For lumbar mobility resulting measurements differed significantly and correlated only moderate between Idiag M360 and Epionics SPINE. Although the different measurement systems are moderate to high correlated to each other, their absolute agreement is limited. This might be explained by differences in their angle definition for lordotic and kyphotic angle, their measurement placement, or their capturing of mobility (static vs. dynamic assessment). Therefore, for long-term evaluation of the back profile, inter-modal comparison of values between different non-invasive devices should be avoided.

Для цитирования: Dreischarf Bettina, Koch Esther, Dreischarf Marcel, Schmidt Hendrik, Pumberger Matthias, Becker Luis. Comparison of three validated systems to analyse spinal shape and motion.. Scientific reports. 2022. DOI: 10.1038/s41598-022-13891-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.