OBJECTIVE

To determine whether hydroxyapatite (HA) bone cement is a suitable material for mastoid cavity obliteration.

STUDY DESIGN &

SETTING

Retrospective case review; tertiary care pediatric hospital.

PATIENTS: Three patients, aged 11 to 16 years, underwent canal wall down mastoidectomy for removal of cholesteatomas.

INTERVENTION: Mastoid cavity obliteration was performed with hydroxyapatite bone cement.

MAIN OUTCOME MEASURES: Failure was defined as the necessity for HA explantation.

RESULTS

All three patients required revision surgery to remove the HA cement. Two patients (one primary and one second look with obliteration) presented with granulations in the mastoid cavity, surrounding the cement. The third patient's intraoperative findings included extensive skull base osteitis with erosion of the posterior and middle fossa dural plates, and fistulae of the lateral and superior semicircular canals. All patients recovered fully after removal of the HA cement.

CONCLUSION

This study raises concerns over the use of HA cement for mastoid cavity obliteration. Three of three implanted patients required revision surgery, two with delayed failure of integration and infection, and one with severe osteitis and significant complications.

Для цитирования: Ridenour Janell S, Poe Dennis S, Roberson David W. Complications with hydroxyapatite cement in mastoid cavity obliteration.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2008. DOI: 10.1016/j.otohns.2008.07.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.