MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpba.2018.09.054

Медицинская библиотека · Journal of pharmaceutical and biomedical analysis · 2018

A method using angiotensin converting enzyme immobilized on magnetic beads for inhibitor screening.

Tang Weiwei, Jia Bingjie, Zhou Jie, Liu Jing, Wang Jiancheng, Ma Dingyuan, Li Ping, Chen Jun

Оценочное исследованиеСтатьяВалидационное исследованиеПеревод в очереди

Аннотация

Angiotensin converting enzyme (ACE), fusing with FLAG tag, was overexpressed in human embryonic kidney 293T cells. This recombinant FLAG-tagged ACE was immobilized on anti-FLAG antibody coated magnetic beads by affinity method in crude cell lysate for the first time. The enzyme-immobilized magnetic beads (ACE-MB), without further cleavage procedure, were used directly to establish a cost-effective and reliable method for screening ACE inhibitors by coupling with fluorescence detection. The enzymatic activity of the ACE-MB was validated based on its Michaelian kinetic behavior towards hippuryl-histidyl-leucine by UHPLC-MS/MS method firstly. Then, several conditions were optimized including amount of magnetic beads, incubation temperature and time in the procedure of ACE immobilization and amount of ACE-MB in the microplate operation. Moreover, this screening assay was validated with Z' factors between 0.71 and 0.81 using four known ACE inhibitors (captopril, lisinopril, fosinopril and fosinoprilat). The developed method was applied for the screening of ACE inhibitors from a small compound library of 45 natural products. As a result, epiberberine and fangchinoline with certain ACE inhibitory activities were screened out in the assay and validated. The results demonstrate the usefulness of this screening method using ACE immobilized on magnetic beads and the advantage of great efficiency with respect to both time and reagents for screening ACE inhibitors.

Для цитирования: Tang Weiwei, Jia Bingjie, Zhou Jie, Liu Jing, Wang Jiancheng, Ma Dingyuan, Li Ping, Chen Jun. A method using angiotensin converting enzyme immobilized on magnetic beads for inhibitor screening.. Journal of pharmaceutical and biomedical analysis. 2018. DOI: 10.1016/j.jpba.2018.09.054.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.