MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00004424-199511000-00002

Медицинская библиотека · Investigative radiology · 1995

Efficacy of gadolinium administration in magnetic resonance imaging screening of patients with complex partial seizures and results of a normal neurologic examination.

Sanders W P, Silbergleit R, Spickler E M, Barkley G L, Mehta B A

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

RATIONALE AND

OBJECTIVES

Magnetic resonance imaging has become a standard screening tool in the evaluation of patients with complex partial seizures. This study prospectively addresses the efficacy, if any, of routinely adding gadolinium-enhanced images to routine T2-weighted images in patients with a normal neurologic examination.

METHODS

One hundred consecutive patients with electroencephalogram and clinical evidence of complex partial seizures and no other neurologic abnormalities were examined prospectively with axial and coronal T2-weighted spin-echo images, followed by axial and coronal gadolinium-enhanced T1-weighted scans.

RESULTS

The scans in 73 patients were interpreted as normal, 14 had nonspecific white matter lesions, 5 had asymmetry of the temporal horns, and 2 had asymmetric signal intensity in the temporal lobes, and the scans in 6 showed abnormal gadolinium enhancement. Of the lesions in the six patients whose scans showed abnormal enhancement, four were seen well on the T2-weighted images. Of the remaining two, one was a small cerebellar venous angioma, and the other, a probable tiny convexity meningioma. One temporal lobe glioma seen on the T2 scans did not enhance with gadolinium.

CONCLUSIONS

Routine administration of gadolinium does not appear to be of benefit in imaging patients with complex partial seizures who are otherwise neurologically normal.

Для цитирования: Sanders W P, Silbergleit R, Spickler E M, Barkley G L, Mehta B A. Efficacy of gadolinium administration in magnetic resonance imaging screening of patients with complex partial seizures and results of a normal neurologic examination.. Investigative radiology. 1995. DOI: 10.1097/00004424-199511000-00002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.