MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00701-019-04020-1

Медицинская библиотека · Acta neurochirurgica · 2019

Frame-based stereotactic biopsy of deep-seated and midline structures in 511 procedures: feasibility, risk profile, and diagnostic yield.

Hamisch Christina A, Minartz Jana, Blau Tobias, Hafkemeyer Vanessa, Rueß Daniel, Hellerbach Alexandra, Grau Stefan J, Ruge Maximilian I

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

We evaluated the feasibility, safety, and diagnostic yield of frame-based stereotactic biopsies (SB) in lesions located in deep-seated and midline structures of the brain to analyze these parameters in comparison to other brain areas.

PATIENTS AND

METHODS

In a retrospective, tertiary care single-center analysis, we identified all patients who received SB for lesions localized in deep-seated and midline structures (corpus callosum, basal ganglia, pineal region, sella, thalamus, and brainstem) between January 1996 and June 2015. Study participants were between 1 and 82 years. We evaluated the feasibility, procedural complications (mortality, transient and permanent morbidity), and diagnostic yield. We further performed a risk analysis of factors influencing the latter parameters. Chi-square test, Student t test, and Mann-Whitney rank-sum test were used for statistical analysis.

RESULTS

Four hundred eighty-nine patients receiving 511 SB procedures (median age 48.5 years, range 1-82; median Karnofsky Performance Score 80%, range 50-100%, 43.8% female/56.2% male) were identified. Lesions were localized in the corpus callosum (29.5%), basal ganglia (17.0%), pineal region (11.5%), sella (7.8%), thalamus (4.3%), brainstem (28.8%), and others (1.1%). Procedure-related mortality was 0%, and permanent morbidity was 0.4%. Transient morbidity was 9.6%. Histological diagnosis was possible in 99.2% (low-grade gliomas 16.2%, high-grade gliomas 40.3%, other tumors in 27.8%, no neoplastic lesions 14.5%, no definitive histological diagnosis 0.8%). Only the pons location correlated significantly with transient morbidity (p < 0.001).

CONCLUSION

In experienced centers, frame-based stereotactic biopsy is a safe diagnostic tool with a high diagnostic yield also for deep-seated and midline lesions.

Для цитирования: Hamisch Christina A, Minartz Jana, Blau Tobias, Hafkemeyer Vanessa, Rueß Daniel, Hellerbach Alexandra, Grau Stefan J, Ruge Maximilian I. Frame-based stereotactic biopsy of deep-seated and midline structures in 511 procedures: feasibility, risk profile, and diagnostic yield.. Acta neurochirurgica. 2019. DOI: 10.1007/s00701-019-04020-1.