MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmri.21567

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2008

Time-resolved dynamic contrast-enhanced MR urography for the evaluation of ureteral peristalsis: initial experience.

Kim Sooah, Jacob Jason S, Kim Danny C, Rivera Rafael, Lim Ruth P, Lee Vivian S

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the feasibility of time-resolved dynamic contrast-enhanced magnetic resonance urography (MRU) for the evaluation of ureteral peristalsis using a data-sharing 3D gradient echo sequence with spiral k-space filling.

MATERIALS AND

METHODS

Eight patients (M=3, F=5, mean 48.1 years) were referred for MRU for the evaluation for renal mass (n=3), hematuria (n=2), urinary tract tuberculosis (n=1), postoperative bladder cancer (n=1), and postoperative ureteric reimplantation (n=1). Dynamic MRU was performed for 120 seconds at 1.5T after intravenous furosemide and gadolinium administration using an oblique sagittal, time-resolved T1 3D gradient echo sequence with 1 second effective temporal resolution. Study quality was assessed based on artifacts and extent of ureteric visualization. Frequency of peristalsis from the renal pelvis to urinary bladder was evaluated for each subject.

RESULTS

A total of 16 ureters were examined. Image quality was good in four ureters, satisfactory in 11 ureters, and poor in one ureter. Mean peristaltic frequency was 3.5 waves per minute (range, 2.5-6.5 waves/minute) in normal ureters (n=11). Five ureters were considered abnormal (one urinary tract tuberculosis and four postsurgical ureters), and all had decreased or no peristalsis (0-1.5 waves per minute).

CONCLUSION

MRU using a time-resolved, data-sharing 3D contrast-enhanced technique is able to demonstrate ureteral peristalsis and permits quantification of ureteral peristaltic frequency.

Для цитирования: Kim Sooah, Jacob Jason S, Kim Danny C, Rivera Rafael, Lim Ruth P, Lee Vivian S. Time-resolved dynamic contrast-enhanced MR urography for the evaluation of ureteral peristalsis: initial experience.. Journal of magnetic resonance imaging : JMRI. 2008. DOI: 10.1002/jmri.21567.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.