MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1121/1.3662061

Медицинская библиотека · The Journal of the Acoustical Society of America · 2012

Comparing closed quotient in children singers' voices as measured by high-speed-imaging, electroglottography, and inverse filtering.

Mecke Ann-Christine, Sundberg Johan, Granqvist Svante, Echternach Matthias

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The closed quotient, i.e., the ratio between the closed phase and the period, is commonly studied in voice research. However, the term may refer to measures derived from different methods, such as inverse filtering, electroglottography or high-speed digital imaging (HSDI). This investigation compares closed quotient data measured by these three methods in two boy singers. Each singer produced sustained tones on two different pitches and a glissando. Audio, electroglottographic signal (EGG), and HSDI were recorded simultaneously. The audio signal was inverse filtered by means of the decap program; the closed phase was defined as the flat minimum portion of the flow glottogram. Glottal area was automatically measured in the high speed images by the built-in camera software, and the closed phase was defined as the flat minimum portion of the area-signal. The EGG-signal was analyzed in four different ways using the matlab open quotient interface. The closed quotient data taken from the EGG were found to be considerably higher than those obtained from inverse filtering. Also, substantial differences were found between the closed quotient derived from HSDI and those derived from inverse filtering. The findings illustrate the importance of distinguishing between these quotients.

Для цитирования: Mecke Ann-Christine, Sundberg Johan, Granqvist Svante, Echternach Matthias. Comparing closed quotient in children singers' voices as measured by high-speed-imaging, electroglottography, and inverse filtering.. The Journal of the Acoustical Society of America. 2012. DOI: 10.1121/1.3662061.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.