MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/s0022215120001139

Медицинская библиотека · The Journal of laryngology and otology · 2020

Pseudo mastoid obliteration with conchal cartilage may be a safe alternative technique for cochlear implantation in canal wall down mastoidectomy with large meatoplasty.

Carnevale C, Til-Pérez G, Arancibia-Tagle D, Tomás-Barberán M, Sarría-Echegaray P

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Safe cochlear implantation is challenging in patients with canal wall down mastoid cavities, and the presence of large meatoplasties increases the risk of external canal overclosure. This paper describes our results of obliteration of the mastoid cavity with conchal cartilage as an alternative procedure in cases of canal wall down mastoidectomy with very large meatoplasty.

METHODS

The cases of seven patients with a canal wall down mastoidectomy cavity who underwent cochlear implantation were retrospectively reviewed. Post-operative complications were analysed. The mean follow-up duration was 4.5 years.

RESULTS

There was no hint of cholesteatoma recurrence and all patients have been free of symptoms during follow up. Only one patient showed cable extrusion six months after surgery, and implantation of the contralateral ear was needed.

CONCLUSION

Pseudo-obliteration of the mastoid cavity with a cartilage multi-layered palisade reconstruction covering the electrode may be a safe alternative in selected patients with a large meatoplasty.

Для цитирования: Carnevale C, Til-Pérez G, Arancibia-Tagle D, Tomás-Barberán M, Sarría-Echegaray P. Pseudo mastoid obliteration with conchal cartilage may be a safe alternative technique for cochlear implantation in canal wall down mastoidectomy with large meatoplasty.. The Journal of laryngology and otology. 2020. DOI: 10.1017/s0022215120001139.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.