OBJECTIVE

To determine if active listening modulates the strength of the medial olivocochlear (MOC) reflex in children.

DESIGN

Click-evoked otoacoustic emissions (CEOAEs) were recorded from the right ear in quiet and in four test conditions: one with contralateral broadband noise (BBN) only, and three with active listening tasks wherein attention was directed to speech embedded in contralateral BBN.

STUDY SAMPLE: Fifteen typically-developing children (ranging in age from 8 to14 years) with normal hearing.

RESULTS

CEOAE levels were reduced in every condition with contralateral acoustic stimulus (CAS) when compared to preceding quiet conditions. There was an additional systematic decrease in CEOAE level with increased listening task difficulty, although this effect was very small. These CEOAE level differences were most apparent in the 8-18 ms region after click onset.

CONCLUSIONS

Active listening may change the strength of the MOC reflex in children, although the effects reported here are very subtle. Further studies are needed to verify that task difficulty modulates the activity of the MOC reflex in children.

Для цитирования: Smith Spencer B, Cone Barbara. The medial olivocochlear reflex in children during active listening.. International journal of audiology. 2015. DOI: 10.3109/14992027.2015.1008105.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.