MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/978-1-4614-1590-9_19

Медицинская библиотека · Advances in experimental medicine and biology · 2013

Spectral and level effects in auditory signal enhancement.

Viemeister Neal F, Byrne Andrew J, Stellmack Mark A

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

Auditory enhancement refers generally to the increased perceptual salience of a spectral region when that region is preceded by its spectral complement, e.g., reinserting a missing component in a harmonic complex makes that component "pop out." One manifestation of enhancement is the increased detectability of a signal in certain spectro-temporal configurations. In the present experiments, detection thresholds were measured for a 2-kHz signal that was masked by an inharmonic complex with a spectral notch centered at 2-kHz. When the masker was preceded by a precursor/adaptor with a spectral gap identical to that of the masker, detection thresholds were lowest when the gap width was 0.6 octave. The amount of signal enhancement, the difference in thresholds between the no-precursor and precursor -conditions, decreased for smaller and larger gap widths. In addition, this general result was robust for precursors such as band-reject noise and harmonic complexes that were different in perceptual quality from the masker. This suggests that grouping/segregation processes do not mediate enhancement as assessed here. Similarly, significant enhancement was observed with precursor-masker level differences over a 40-dB range. Overall, these results further indicate that frequency resolution is a dynamic process that depends on spectro-temporal context. They also are consistent with a mechanism involving adaptation of inhibition that likely occurs at low levels in the auditory system.

Для цитирования: Viemeister Neal F, Byrne Andrew J, Stellmack Mark A. Spectral and level effects in auditory signal enhancement.. Advances in experimental medicine and biology. 2013. DOI: 10.1007/978-1-4614-1590-9_19.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.